Datum Systems PSM-500, 500H & 500L VSAT/SCPC Modem Specification
Rev. 0.86
A-11
16QAM Modulation Viterbi FEC Performance
Waterfall curves for the common Viterbi FEC at the available Code Rates for 16QAM modulation
modes are shown in the graphs below. TPC 16QAM performance is shown with the TPC FEC data
later.
Viterbi FEC Performance for 16QAM with and without Reed-Solomon
Required Eb/No in dB dB - Typical
Rate -->
1/2 3/4 5/6 7/8
RS Opt--> None 4 None 4 CT-5 None 4 None 4 CT-5
BER 61000 61004 61010 61014 61215 61020 61024 61030 61034 61235
1.00E-03 5.65 5.13 7.24 6.68 6.60 7.92 7.49 8.46 7.96
1.00E-04 6.38 5.38 8.08 6.93 6.79 8.74 7.75 9.24 8.18
1.00E-05 7.02 5.57 8.89 7.15 6.95 9.51 8.00 10.01 8.40
1.00E-06 7.65 5.70 9.62 7.35 7.12 10.23 8.23 10.72 8.60
1.00E-07 8.23 5.84 10.28 7.54 7.26 10.92 8.45 11.33 8.79
1.00E-08 8.75 5.97 10.87 7.72 7.39 11.53 12.15 11.98 8.96
1.00E-09 9.24 6.11 11.47 7.91 7.53 12.02 20.67 12.54 9.13
Datum Systems M500 Modem Performance
61000 - Vit 16QAM, Rate 1/2
61004 - Vit 16QAM, Rate 1/2, RS 4
61010 - Vit 16QAM, Rate 3/4
61015 - Vit 16QAM, Rate 3/4, RS 5
61020 - Vit 16QAM, Rate 5/6
61025 - Vit 16QAM, Rate 5/6, RS 5
61030 - Vit 16QAM, Rate 7/8
61035 - Vit 16QAM, Rate 7/8, RS 5
1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13
1E-10
1E-9
1E-8
1E-7
1E-6
1E-5
0.0001
0.001
0.01
0.1
Eb/No
BER
DATUM
SYSTEMS
Viterbi 16QAM
Vue de la page 10